 High Performance Beta Range
RoHS
Pb
GreentubeTM SL1002A Series Gas Plasma Arrester
(R)
The Broadband OptimizedTM SL1002 series has been especially developed for use in broadband equipment. Unique design features offer high levels of performance on fast rising transients in the domain of 100V/S to 1KV/S, which are those most likely from induced Lightning disturbances. These devices have Ultra low capacitance (typically 1.2pF or less) and present insignificant signal losses up to 1.5GHz. These devices are extremely robust and are able to divert a 5000A pulse without destruction. For AC Power Cross of long duration, overcurrent protection is recommended.
FEATURES
* RoHS compliant and Lead-free * Ultra Low Insertion Loss * Surface mountable * 5KA surge capability tested with 8/20S pulse
as defined by IEC 61000-4-5
* Excellent response to fast rising transients. * Can be used to meet Telcordia GR1089 3.5 4.20.2
without series resistance
* 10/700 6KV capability, as per ITUT k.21, enhanced test level * 2000 Amp 2/10S surge rating * Meets FCC part 68 10/160s waveform, 200A test and 5.0 6.0 0.2
10/560s waveform 100A test.
Applications:
* Broadband equipment. * ADSL equipment. * XDSL equipment. * Satellite and CATV equipment. * General telecom equipment.
1.3
RECOMMENDED PAD LAYOUT
0.8 SL1002AxxxC 4.30.3
6.2 0.2
GDT SHOWING SEATING PLANE FOR SL1002AxxxSM
SL1002AxxxSM
6.2 0.2
SL1002AxxxSM
All dimensions in mm
Mechanical Specifications:
Weight: Materials:
0.63g (0.022 oz.) Electrode Base: Nickel Iron Alloy Electrode Plating: Bright Sn Body: Ceramic `LF' logo, Voltage and date code
Device Marking:
325
w w w. l i t t e l f u s e . c o m
High Performance Beta Range
RoHS
Pb
GreentubeTM SL1002A Series Gas Plasma Arrester
(R)
LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
DC Breakover Voltage @100 V/s Volts Part Number* SL1002A090 SL1002A230 SL1002A250 SL1002A260 SL1002A350 SL1002A600 MIN 70 184 200 210 280 480 MAX 120 276 300 310 420 720 MAX Dynamic Breakover Voltage1 100 V/s Volts 360 400 400 400 500 800 1kV/s Volts 700 500 500 500 600 900 AC Discharge Current2 Amps 5 5 5 5 5 5 Max Repetitive Impulse Current3 kAmps 5 5 5 5 5 5 MAX Single Impulse Current 2/10 s kAmps 2 2 2 2 2 2 2/350 s kAmps 2 2 2 2 2 2 Max Leakage Current4 nAmps 100 100 100 100 100 100 Nominal On-state Voltage @1A Volts 20 20 20 20 20 20
Holdover Voltage5 Volts 50 135 135 135 135 135
*Max capacitance is 1.2 pF, measured at 1 MHz, zero volt bias
Notes:
1. 2. 3. 4. 5. Comparable to the silicon measurement Switching Voltage (Vs) 10 shots, AC 60Hz, 1s duration 10 shots, 8/20s waveform per IEC 61000-4-5 Measured at 100V, except 90VDC devices wich are measured at 50V Tested according to ITU-T Rec. K.12
8
GAS DISCHARGE TUBES
Voltage vs Time Characteristic
Max dynamic breakover voltage
Typical Insertion Loss
@ 1.0 GHz = 0.01 dB @1.4GHz = 0.1dB @1.8 GHz = 0.53 dB @2.1 GHz = 0.81 dB @2.45 GHz= 1dB @2.8 GHz = 1.2 dB @3.1 GHz = 1.5dB
Voltage (V)
Hold-over voltage
@3.5 GHz = 2.1 dB
On-State voltage
0
200
400
600 Time (ns)
800
1000
1200
w w w. l i t t e l f u s e . c o m
326


▲Up To Search▲   

 
Price & Availability of SL1002A090

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X